• Surtron 300 HP

• Two output channels for monopolar cutting
• Two independent setting and output channels for monopolar coagulation more frequently

CONTROLLED CUTTING PROCEDURES
• cutting currents for eschar free incision
• Cutting current with selectable coagulating property for bleeding controlled dissection
• Low capacitive coupling by current endoscopic procedures Slow BLEND


DOUBLE PROCEDURES SUBSIDIARIES COAGULATION
• SPEEDY Coag Coag DEEP ** * and two operators
• SPRAY COAG achievable with handpiece or pedal


WIDE BIPOLAR FEATURES
• Bipolar cutting with bleeding control
• Cutting current Slow BLEND
• Start and Stop automatic activated separately


TOTAL SAFETY FOR PATIENT AND SURGEON
• Acceptability of contact impedance between the patient’s body and the neutral plate constantly verified by the electronic control Skin Plate Electronic Control called SPEC
• Continuous monitoring of leakage current
• Change in automatically compensated mains voltage before starting the RF power output


CUSTOM PROCEDURES
• Independent choice of coagulation currents and power levels of each of the two operators
• Ten configurable personal procedures and immediately recallable


CONDUCT OF EXTENSIONS AND SIGNAL CONNECTION
• outputs for connections driven argon plasma units and smoke aspirator


AUTOMATIC SELF-DIAGNOSIS WITH SURTRON 300 HP
• Automatic diagnostic control of the actual complete electronic drive functionality and accessories connected and coded report of found failures


* Coag SPEEDY is also called Fulgurate or Forced
** Coag DEEP is also called Pin Point, Dessicate or Soft


 


FEATURES
Code 10400.802
Max output power monopolar pure CUT
300 W – 300 Ω
Max output power monopolar cut-coag CUT80%
250 W – 300 Ω
Max output power monopolar cut-coag CUT60%
200 W – 300 Ω
Max output power monopolar cut-coag CUT40%
150 W – 300 Ω
Max output power monopolar cut ENHANCED
200 W – 500 Ω
Max output power monopolar cut-coag BLEND
200 W – 300 Ω
Max output power monopolar coag SPEEDY
100 W – 500 Ω
Max output power monopolar coag DEEP
100 W – 200 Ω
Max output power monopolar coag SPRAY
70 W – 2000 Ω

Max output power monopolar coag SPRAY ARGON
70 W – 2000 Ω
Max output power bipolar CUT
120 W – 50 Ω
Max output power bipolar cut-coag CUT80%
120 W – 50 Ω
Max output power bipolar cut-coag CUT60%
120 W – 50 Ω
Max output power bipolar cut-coag CUT40%
100 W – 50 Ω
Max output power bipolar cut-coag BLEND
120 W – 150 Ω
Max output power bipolar coag COAG
120 W – 50 Ω
Vessel sealing
200 W – 50 Ω

Working frequency Monopolar / Bipolar
425 kHz / 525 kHz
Patient circuit
F
Selectable input voltage
115 – 230 Vac
Mains frequency
50 – 60 Hz
Electrical input power
1000 VA

Size WxHxD
470x150x400 mm
Weight
17,5 Kgs


 


CONTROLS
Patient/Plate circuit monitoring
Output power monitoring
Self check control
H.F. Leakage currents control
Compensation of mains fluctuation


 


SAFETY
EN60601-1
EN60601-1-2
EN60601-2-2
Electrical classification: CF
MDD 93/42 / EC: II b



Write a review

Note: HTML is not translated!
    Bad           Good
Captcha

Surtron 300 HP

  • Brands LED SpA
  • Product Code: 10400.802
  • Availability: 6-7 Days
  • 2,146,300 Ft.

  • Ex Tax: 1,690,000 Ft.

Related Products

Surtron ABC

Surtron ABC

Argon module that can be connected with a compatible electrosurgical unit, specific for coagulatio..

2,019,300 Ft. Ex Tax: 1,590,000 Ft.

Surtron EVAC

Surtron EVAC

 This is an aspiration and filtering system for the smokes produced during the surgical procedu..

349,000 Ft. Ex Tax: 274,803 Ft.

Tags: electrocauter